Voltage: 0.00 ~ 600V
Current: 0.00mA ~ 30.0A
Phase: 0 ~ 360°
Harmonics: 1-50 times
Active power: 0.00W-18.0kW
32-bit embedded processor Design
The MiNi is lightweight and easy to use
Electric energy, power, voltage and current test
Harmonic phase frequency power factor test
Electric energy: 0.0Wh-9999kWh
Work energy | At the same time, the phase, true RMS voltage, true RMS current, active power, reactive power, apparent power, active power, reactive power, apparent power, power factor,1~50 harmonics, harmonic ratio, real-time disy of current and voltage waveform, leakage current, frequency, phase,1 SEC ~999 SEC timing data storage, etc. |
Electricity source | 6LR61,9V DC, continuous use for about 7 hours |
Test mode | Forceps CT; True RMS mode |
Mouth size | Ф7.5mm×13mm |
Measuring range | Voltage: AC 0.1V to 600V(voltage frequency range :40Hz to 70Hz) |
Current: AC 0.0mA to 30.0A (current frequency range :40Hz to 70Hz) | |
Active power: 0.00W~18.0KW/ Reactive power: 0.00Var~18.0KVar/ Visible power: 0.00VA~18.0KVA | |
Active power: 0.0Wh~9999KWh/ Reactive power: 0.0VARh~9999KVARh/ Visual power: 0.0VAh~9999KVAh | |
Phase: 0° ~ 360°/50Hz Harmonic frequency: 1~50 times/harmonic ratio: 0percent~100percent/ Frequency: 40.0Hz ~ 70.0Hz Power factor: -1 ~1 | |
Resolution rate | Phase: 1°/ Voltage: 0.1V/ Current: 0.1mA/ Visual power: 0.01VA/ active power: 0.01W/ reactive power: 0.01Var/ Visual power: 0.1VAh/ active power: 0.1Wh/ reactive power: 0.1VARh/ Harmonic ratio: 1percent/ Frequency: 0.1Hz/ power factor: 0.01 |
Measurement accuracy
(23℃±5℃,80percentRH below) |
Phase: ±2° (Note: phase error under working conditions: ±3° for 10mA ~ 30A; ±5° below 10mA; In order to ensure the accuracy of measurement, voltage should not be less than 5V, current should not be less than 5mA) |
Voltage: ±1.5percent±5dgt/ Current: ±1.5percent±5dgt/ active power: ±2percent±5dgt/ reactive power: ±2percent±5dgt/ apparent power: ±2percent±5dgt/ active power: ±2percent±5dgt/ reactive power: ±2percent±5dgt/ apparent power: ±2percent±5dgt/ harmonic ratio (I> 30mA V> 30V) : ±(2percent 6dgt)/ Frequency: ±1Hz/ Power factor: ±0.04 |
Wave shape | Can disy 1~4 complete cycle waveform (50Hz) |
Harmonic wave | 1~50 times |
Timing storage | Close:关闭Timing storage功能(开机默认关闭)
1 to 999: Automatically stores data every 1 to 999 seconds |
Data storage | 4000 groups |
Timed shutdown | 10min: Automatic shutdown of instrument in 10 minutes (automatic shutdown in 10 minutes by default)
Close: disables the automatic shutdown function |
Disy mode | OLED liquid crystal disy |
LCD size | 35 mm x 21.5 mm; Disy domain 32mm x 15mm |
Shift gears | Automatic shift |
Speed rate | ADC sampling rate: 1MSPS; Disy rate: 10 times/second |
Instrument size | Length width and thickness 220mm×45mm×30mm |
Line voltage | Line test below 600V |
Function switch | Press the MODE key to switch the disy of each function page |
Instrument quality | Meter 220g (including battery); Total weight 0.57kg(including outer packing) |
Working current | Max 17mA |
Working temperature and humidity | -10℃ ~ -10℃ ~ 60℃; 70percentRh below 40℃; 80percentRh below |
Storage temperature and humidity | -10℃ ~ 60℃; 70percentRh below |
电池电压 | When the battery voltage is lower than 6.8V, the empty core battery icon is disyed to remind you to rece the battery |
Data retention | Press the HOLD key to HOLD the data, then press the Hold key to cancel the hold |
Data retrieval | 按 READ 键进入Data retrieval,按上下箭头键翻阅存数据 |
Overflow disy | 量程溢出功能:“OL”符号显示 |
Invalid disy | "----" or "--" |
Insulation strength | 2000V/rms(Before the front and rear ends of the instrument housing) |
Suitable for safety rules | IEC1010-1,IEC1010-2-032, pollution level 2,CAT Ⅲ(600V)
|