UT216B Main features:
1, AC current measurement, the maximum range of 600A;
2. Ac voltage and current are all measured with true RMS;
3, large capacitance measurement, maximum 60mF;
4, frequency measurement, maximum 1MHz;
5. Non-contact voltage detection (NCV) is realized through the sensor at the top of the clamp head;
6, with VFC function, can measure the AC voltage and AC current with frequency conversion interference;
7, with a flashlight function, can be used in the pliers to hook the wire to be tested to provide lighting
| Basic function | The range of | Basic accuracy |
| Model number |
|
UT216B |
| Ac current (A) | 60A/600A | ±(2.5%+5) |
| Ac current frequency response |
|
40Hz ~400Hz |
| Ac voltage (V) | 6V/60V/600V/750V | ±(1.2%+5) |
| Ac voltage frequency response |
|
40Hz ~400Hz |
| Dc voltage (V) | 600mV/6V/60V/600V/1000V | ±(0.8%+1) |
| Resistance (Ω) | 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ | ±(1%+2) |
| Capacitance (F) | 99.99nF/999.9nF/9.999μF/99.99μF/999.9μF/9.999mF/59.99mF | ±(4.0%+5) |
| Frequency (Hz) | 10Hz~1MHz | ±(0.1%+4) |
| Special function | ||
| Maximum disy |
|
5999 |
| 自动The range of |
|
√ |
| Opening size |
|
30mm |
| True effective value |
|
√ |
| Diode test | About 3.0V | √ |
| VFC |
|
√ |
| NCV |
|
√ |
| The number holds |
|
√ |
| Relative measurement |
|
√ |
| Maximum/minimum value |
|
√ |
| LCD backlight |
|
√ |
| Flashlight |
|
√ |
| Automatic shutdown | About 15 minutes | √ |
| On or off the buzzer |
|
√ |
| Low voltage disy | ≤3.6V | √ |
| Input protection |
|
√ |
| Input impedance | ≥10MΩ | √ |
| General characteristics | ||
| Power supply | AAA 1.5V × 3 | |
| LCD size | 38mm ×24 mm | |
| Fuselage color | Red gray | |
| Fuselage weight | 231.7g | |
| Fuselage size | 220mm ×75mm ×40mm | |
| Standard parts | Battery, watch pen | |
| Standard packing | Color boxes, cloth bags, instructions, warranty cards | |
| Standard packing数量 | Forty sets | |
| Standard packing尺寸 | 485mm×345mm×385mm | |
| Standard packing箱毛重 | 18Kg
|
|