Product Description:
JK2826 high precision digital bridge is a kind of multifunctional component parameter tester for testing various electronic components. 7 inch 800x480 color TFT LCD disy.
High speed, stable, 20Hz-5MHz multi-frequency points and 0.05percent accuracy can meet the production line quality control, incoming inspection and laboratory measurement requirements
Performance Characteristics:
■ New 32-bit core processor, complete data comparison with foreign first-class equipment
■7 "True color TFT monitor
■20 Hz-5MHz test frequency
■0.05percent basic measurement accuracy, fast test speed (75 times/s)
■ Graphic scanning analysis function, support frequency/level/offset scanning, insight into the characteristics of the tested parts
■ Multi-parameter test function.
■ Automatic level control ALC function for testing voltage or current
■ Output impedance of four different signal sources: 30 Ω, 50 Ω,100 Ω,10/CC
■ Built-in comparator, 10-stop sorting and counting function
■ 10-point list scan
■ Internal 100 sets of setup files,U disk 500 sets of test files saved or called
■ 0V, 1.5V and 2V internal DC bias voltage
■ Optional ±5V (±100mA) DC bias source or 1A DC bias source
■ The instrument software version can be upgraded and updated through U disk
■U disk copy screen, real-time data saving, can support FAT16, FAT32 file system
■ Standard RS232C,USB HOST,USB DEVICE,HANDLER, headphone interface, foot switch interface; Optional GPIB,LAN
Technical parameters:
Model number |
JK2826 |
|
Test frequency |
20Hz-5MHz, 0.01Hz resolution |
|
Test parameters |
|Z|,|Y|, C,L,X, J, B,R,G,D,Q,θ,DCR |
|
Basic measurement accuracy |
0.05% |
|
Equivalent circuit |
Series, parallel |
|
Mathematical function |
Absolute value deviation, percentage deviation |
|
Range mode |
Automatic, hold, manual selection |
|
Trigger mode |
Internal, manual, external, Bus |
|
Measurement speed (≥1kHz) |
Fast: 75 times/s, medium speed: 12 times/s, slow speed :3 times/s |
|
The average number of times |
1-255 |
|
Delay time |
0-60s, step by 1ms |
|
Calibration function |
Open/short/load |
|
List scan |
10点List scan功能 |
|
Disy mode |
Direct reading,△,△percent, V/I (measured voltage/current monitoring) |
|
The monitor |
800>480 RCB7英寸16: 9 TFT LCDThe monitor |
|
Test signal |
||
Output impedance |
30 Ω, 50Ω,100 Ω,10 /CC optional |
|
Test signal电平 |
Normal: 5mV-2V Accuracy: 10percent, 1 mV step. Constant level :10 MV-1 V Accuracy: 5percent, 1 mV step |
|
Dc offset source |
Inside |
0V, 1.5V,2V, accuracy: 1percent |
Optional |
± 5V ( ± 100mA) DC bias source selection 1A:0-1A DC bias source option |
|
Disy range |
||
|Z|,R, X |
0.01mΩ-99.9999MΩ |
|
DCR |
0.001mΩ-99.9999MΩ |
|
|Y|,G, B |
0.00001 μ S one 99.9999S |
|
C |
0.00001pF 9.9999F |
|
L |
0.00001 μ H one 9999.99H |
|
D |
0.00001-9.9999 |
|
Q |
0.00001-9999.9 |
|
θ (DEG) |
-179.999 ° -179.999 ° |
|
θ (RAD) |
-3.14159 ° I 3.14159 ° |
|
Other |
||
Comparator function |
十档: (九档合格,一档不合格) ,另有AUX档 |
|
Multiparameter |
Optionally select four parameters for simultaneous measurement and disy |
|
Curve scanning function |
Under a variety of test conditions, the measured parts for graphic scanning sorting |
|
Memory |
Inside存储、USB扩展存储 |
|
Interface |
标配RS232C、HANDLER、 USB HOST, USB DEVICE、耳机Interface、脚踏Interface;可选GPIB、LAN |
|
Size |
375m (W) x 135mm (H) x 350m(L) |
|
Net weight |
About 7 kilograms |
|
Standard parts
|
26011B Four end Kelvin test cable 26005B Four-terminal test box 26010 . Four-terminal test box |
|
可Optional件
|