Beijing Yingyehua Technology Co., LTD

Consultation Hotline 17710831251

Beijing Yingyehua Technology Co., LTD
CH | EN
Beijing Yingyehua Technology Co., LTD

Consultation Hotline 17710831251

Beijing Yingyehua Technology Co., LTD

Your Position:Home > Products Center > 固纬Gwinstek > GPT-9600 series safety tester

  • GPT-9600 series safety tester

    Model:GPT-9600

    Brand:固纬Gwinstek

    Introduction:100VA AC test capability 240×48 ice blue dot matrix LCD true RMS current measurement ARC detection zero Open operation using PWM technology, improve test efficiency and reliability Light weight, easy to operate

  • Rapid selection

    Model number The main function of Capacity Zero crossing open Standard interface
    GPT-9601 AC 100VA YES I/O
    GPT-9602 AC/DC 100VA YES I/O
    GPT-9612 AC/IR 100VA YES I/O
    GPT-9603 AC/DC/IR 100VA YES I/O

    Detailed specifications
    AC耐压
    Output voltage range 0.10kV~5.00kV ac
    Output voltage resolution 10V
    Maximum rated load 100VA(5kV/20mA)
    Maximum rated current 20mA(0.5kV<V≤5kV);5mA(0.1kV≤V≤0.5kV)
    Output voltage waveform Sine wave
    Output voltage frequency 50Hz/60Hz Optional
    Voltage regulation rate ±(1.5percent 2 counts)[full load → no load]
    Accuracy of voltmeter ±(1.5percent read value 2 counts)
    Current measurement range 0.01mA~20.0mA
    Optimal current resolution 0.01mA/0.1mA
    Current measurement accuracy ±(2.0percent read value 5 counts) when HI SET < 1.00mA; ±(2.0percent read value 3 counts) when HI SET≥1.00mA
    Current determination accuracy ±(3.0percent SET value 5 counts) when HI SET < 1.00mA; ±(3.0percent SET value 3 counts) when HI SET≥1.00mA
    Windows comparison mode There is
    ARC detection There is
    RAMP up time 0.1s fixed
    Timing (test time) OFF,1s~180s
    GND ON
    DC耐压
    Output voltage range 0.10kV~6.00kV dc
    Output voltage resolution 10V
    Maximum rated load 25W(5kV/5mA)
    Maximum rated current 6mA(0.5kV<V≤6kV);2mA(0.1kV≤V≤0.5kV)
    Voltage regulation rate ±(1.5percent 2 counts)[full load → no load]
    Accuracy of voltmeter ±(1.5percent read value 2 counts)
    Current measurement range 0.01mA~6.00mA
    Optimal current resolution 0.01mA
    Current measurement accuracy ±(2.0percent read value 5 counts) when HI SET < 1.00mA; ±(2.0percent read value 3 counts) when HI SET≥1.00mA
    Current determination accuracy ±(3.0percent SET value 5 counts) when HI SET < 1.00mA; ±(3.0percent SET value 3 counts) when HI SET≥1.00mA
    Windows comparison mode There is
    ARC detection There is
    RAMP up time 0.1s fixed
    Timing (test time) OFF,1s~180s
    GND ON
    Insulation resistance
    Output voltage 50V, 100V, 250V, 500V, 1000V dc
    Output voltagePrecision ±(3.0percent Set value 1 count)[no load]
    Resistance measurement range 1MΩ~2000MΩ
    Test voltage Measuring range Precision
    50V/100V/250V 1~50MΩ;51~2000MΩ ±(5percent read value 2MΩ); ±(10percent read value 2MΩ)
    500V/1000V 1~500MΩ;501~2000MΩ ±(5percent read value 2MΩ); ±(10percent read value 2MΩ)
    Windows comparison mode There is
    Output impedance 600kΩ
    RAMP up time 0.1s fixed
    Timing (test time) OFF,1s~180s
    GND OFF(fixed)
    测试方式*
    A single ACW, DCW, IR
    Automatic AC-IR, IR-AC, DC-IR, IR-DC
    Interface
    Remote terminal (front) Standard configuration
    Signal I/O Standard configuration
    Show

    240×48 ice Blue Dot Matrix LCD
    Power supply

    AC 100V~120V/220V~240V±10%,50/60Hz
    Power loss

    400VA Max
    尺寸&重量

    330(W)×148(H)×385(D)mm
    *“测试模式”与选机型There is关


    Tel:
    Mobile:    
               17710831251    

    Address:Room 2109B, 19th Floor, No. 18 Zhongguancun Street, Haidian District, Beijing

    Email: info@yingyehua.com

    京ICP备2022018247号-1