Characteristic
Short-circuit test: current about 30A, internal resistance about 40mΩ
Dynamic test: 10 files,0.1Hz~1kHz
Dynamic list test: 10 files,100 steps/file
Comprehensive list test: 10 files,20 steps/file
Battery test: 999.99AH
Global Settings file: 20 groups
Triggers: internal triggers, bus triggers, and external triggers
Interface: Standard RS232C and USB interface and Handler interface
Programming language: SCPI and simple communication protocol
Disy: VFD disys
Support 4W remote test function
Specifications
Rated input | 300W、150V、30A |
Constant current | 0-3A: Resolution: 0.0001A accuracy: 0.05percent 0-30A: resolution: 0.001A accuracy: 0.1percent |
Constant voltage | 0-18V: Resolution: 0.001V accuracy: 0.05percent 0-150V: resolution: 0.01V accuracy: 0.05percent |
Fixed power | 0-100W: Resolution: 0.001W Accuracy: 1percent Above 100W: resolution: 0.01W accuracy: 1percent |
Constant resistance | 0.1 ~ 99Ω : Resolution: 0.01Ω Accuracy: 1percent 100 ~ 4kΩ : Resolution: 0.1Ω Accuracy: 1percent |
Monitor | Voltmeter accuracy: 0.05percent
Ammeter accuracy: 0.1percent Battery charging time: 0~1000 hours Battery power detection: 0~999AH Battery standing time: 0~1000 hours Number of battery cycles: 0~10000 |
Comprehensive test | Discharge - charge - discharge - Stand |
Battery capacity test | MAX 999AH |
Interface | RS232CInterface |
Protect | 5级安全Protect |
Other | VFD disy,4W remote test, intelligent fan cooling |
Power requirements | AC 198V-242V, 50Hz-60Hz
20W MAX |
Size and weight | 264 (W) x 107 (H) x 350 (D)
Weight: 5kg |
Attachment | ATL509 Test Cable |