Characteristic
The AT9210A is available for 5kVAC/10mA voltage and 6kVDC/5mA voltage test
Controllable sine generator: in the AC output can be set to work at 50 or 60Hz, no longer limited by line voltage;
Linear power amplifier: The distortion of voltage waveform is small, simple control and high reliability
Output voltage closed-loop control
Single-machine AC withstand voltage test, DC withstand voltage test and can be tested through the project Settings, multi-item sequential test
Specifications
Test function | Ac withstand voltage, DC withstand voltage |
Interface | RS232/Handler |
Arc detection | Level 9 (AC/DC) |
Other functions | List Settings
Discharge function 5 "True color LCD touch screen |
Ac withstand voltage | |
Rated output | AC 5.000kV/10mA |
Output voltage | 0.050kV-5.000KV AC
Resolution: 1V |
Voltage accuracy | 2% of reading + 5 digits |
Voltage adjustment rate | 2% of reading +5V
(from empty to full) |
Output frequency | 50Hz or 60Hz -- is optional |
Measure the current | 0.001mA-10.00mA
Resolution: 0.001/0.01 |
Current accuracy | 2percent x reading 5 words |
Voltage rise time | 0.1s-999.9s |
Test time | 0.2s-999.9s |
Voltage drop time | 0.1s-999.9s |
Dc voltage resistance | |
Rated output | DC 6kV/5mA |
Output voltage | 0.050kV-6.000kV DC
Resolution: 1V |
Voltage accuracy | 2% of reading + 5 digits |
Voltage adjustment rate | 2% of reading +5V |
Current measurement | 0.1μA-5.000mA |
Current accuracy | 2% of reading +5 digits |
Voltage rise time | 0.1s-999.9s |
Test time | 0.2s-999.9s |
Voltage drop time | 0.1s-999.9s |
Power requirements | 198V ~ 242V 50/60Hz
400VA |
Size and weight | 270mm(W)x130mm(H)x450mm (D)
10kg |
Attachment | ATL900E Voltage test cable,ATL108 communication cable,ATL900E-1 High voltage test rod |