Characteristic
Ac voltage test rated output: 5kVac/100mA
Dc voltage test rated output: 6kVdc/10mA
Rated output for insulation test: 2.5kVdc/9999MΩ
Standard RS232,Handler automation interface
ARC detection function
10 "TFT-LCD disy
Specifications
| Test function | Ac voltage resistance, DC voltage resistance, insulation resistance |
| Interface | USB-HOST 、 RS232/RS485 、HANDLER 、报警灯Interface、外部遥控Interface |
| Standard configuration | 5kV、100mA、500VA |
| Comparator | Upper and lower limit intelligent decision function, can automatically identify defective products, while providing sound and light alarm |
| Protection function | Automatic overvoltage and overcurrent include |
| Other functions | List Settings
Discharge function 5 "True color LCD touch screen |
| Ac withstand voltage | |
| Rated output | AC 5.000kV/100mA |
| Actual output power | 500VA |
| Output voltage | 100~5000 V AC
Resolution: 1V |
| Voltage accuracy | 2% of reading + 5 digits |
| Voltage adjustment rate | ± (2percent x set value 5V) |
| Voltage stationarity | ± (0.4percent× set value 1V)/min, no load, full load |
| Output waveform distortion | Resistive load: < 2percent |
| Output frequency | 50Hz or 60Hz -- is optional |
| Short circuit current | >200mA |
| Voltage measurement | 0.10 ~ 5.00kV
Resolution: 0.01kV |
| Voltage measurement准确度 | (1.5% of reading+1 counts) |
| Measure the current | 0.000~3.500/3.00~100.00 mA
Resolution: 0.001/0.01mA |
| Current accuracy | 2percent x reading 5 words |
| Dc voltage resistance | |
| Rated output | DC 6kV/10mA |
| Actual output power | 60VA, ≥90% |
| Output voltage | 0.1kV-6.000kV DC
Resolution: 1V |
| Voltage accuracy | 2% of reading + 5 digits |
| Voltage adjustment rate | ±(1.5percent x read value 1 word) |
| Output ripple | < 5percent (6kV/1mA resistive load) |
| Current measurement | 0.0~350.0/300~3500/3000~9999 μA/10mA
Resolution: 0.1/1/10μA/0.01mA |
| Current accuracy | 百分之二的阅读 |
| Insulation resistance | |
| Rated output | DC 2.5kV/9999MΩ |
| Output voltage | 100~2500V DC
Resolution: 1V |
| Voltage accuracy | 2percentx sets the value to 5V |
| Drop voltage | > 90percent, drop resistance 10MΩ (1percent x range) |
| Measuring range | 1MΩ-9999MΩ, resolution 1 Mω |
| Resistance accuracy | Range: (1 ~9999) MΩ, resolution: 1MΩ
Judgment error: (100-499) V, 1~1000,±(8percent× reading value of 2 words) 1000~2000,±(12percent× read value of 2 words) (500-2500V), 1~199,±(2percent× read value 2 words), 200~999, ± (5percent× read value of 2 words) 1000~9999, ± (15percent× set value 2 words |
| Power requirements | 198V~242V AC
50/60Hz |
| Size and weight | 400(W)x200(H)x503.5(D)
20kg |
| Attachment | ATL900E Voltage test cable
ATL108 communication cable ATL900E-1 High Voltage Test stick |